User Tools

Site Tools


postproc:pcscancelalarmcont
Program Name

pcsCancelAlarmCont

PCS stream-state

group: TPP table: TPP state: CANCELALARM

Description

pcsCancelAlarmCont provides one of the connection points between the PCS system and the post processing alarm system. For each event found it the configured PCS stream-state, a CMS message is sent to the alarmdec_pp program (post-processing alarm) and to the alarmdec program on EACH of the real-time systems by means of the sendcancel program.

The goal of pcsCancelAlarmCont is to cancel any actions that may have been taken by the alarm systems for this event. But pcsCancelAlarmCont has no way of telling which alarm systems have emitted notifications. So pcsCancelAlarmCont tries to send the cancellation message to ALL of the alarm systems. The program (alarmevent) which publishes the alarm cancellation messages into CMS first queries the database of the alarm system in question. If no alarm actions have been scheduled or taken by that alarm system, then no cancellation message is sent to that alarm system.

This system needs to be monitored to see how it behaves when a real-time system is shut down such as for maintenance. Does it gracefully handle the inablity to connect to an alarm system database?

There is the possibility that an RT system could issue alarms for an event and then become inoperable. In that case, pcsCancelAlarmCont would not be able to cancel the alarms issued by that RT system. To ensure that an event deletionmessage gets submitted to PDL, pcsCancelAlarmCont run cancelEvtPrm2PDL for this action.

pcsAlarmCont runs the basic PCS client loop:

  • queries for the next event in its assigned stream-state
  • if an event is found, run alarmcancel <evid> and cancelEvtPrm2PDL <evid>
  • if alarmcancel and cancelEvtPrm2PDL succeeded, set stream-state event result to 1 and repeat the loop
  • if alarmcancel or cancelEvtPrm2PDL failed, set stream-state event result to 100 and repeat the loop
  • if no event is found, sleep 30 seconds and repeat the loop
Program Location

post-proc systems: /home/ncss/ncpp/bin/

Configuration File

none

Source of Database name
Cron Starter Program
0,10,20,30,40,50 * * * * /home/ncss/ncpp/bin/startPcsTasks
Log File

/home/ncss/ncpp/logs/pcsCancelAlarmCont.log

Other Programs Called
  • /home/ncss/ncpp/bin/alarmcancel:
    • reads config file /home/ncss/ncpp/conf/alarmcancel.cfg for list of sendcancel config files
    • for each sendcancel config file, calls sendcancel -c <config> -a * <evid>
  • /home/ncss/run/bin/sendcancel:
    • Reads its config file for database and CMS connection parameters.
    • Queries the configured database for alarm actions for the event.a
    • If alarm actions are present on this system's database, publishes CMS message with subject read from its config file.
postproc/pcscancelalarmcont.txt · Last modified: 2018/01/09 15:52 by 127.0.0.1